Radiant floor heating repair in Santa Fe: cold zones, manifolds, pumps, mixing valves, and loop leaks. Call Lobo Tech at 505-316-4231.

Lobo Tech repairs radiant floor heating systems in Santa Fe, including manifolds, pumps, zone controls, mixing valves, and leaking loops. We check how heat reaches the affected rooms and use pressure tests or thermal imaging where appropriate. Floor access is discussed only after the evidence identifies where a repair is needed.

Content reviewed 2026-10-01.

Locating a radiant heating leak

A pressure drop in an isolated loop can help identify a leak. Thermal imaging may help narrow the area when floor conditions allow a temperature difference to show. We check accessible manifold fittings and isolate loops before discussing any opening in the floor.

Restoring heat to existing floors

Radiant systems deliver heat through tubing or electric elements in or beneath the floor. In hot-water systems, a cold area may come from a control, actuator, circulation problem, or loop fault. The repair should address that cause while preserving the floor wherever practical.

Mixing valves and temperature controls

A hot-water radiant system needs a suitable supply temperature and flow. A faulty mixing valve, pump, or control can leave rooms cold or make temperatures difficult to manage. We check these components and the boiler operation before recommending replacement equipment.

Slab, staple-up, and the leak you cannot see

Radiant in Santa Fe is either tubing in a slab or tubing under a wood floor. A slab leak is a location problem first. We do not jackhammer a guess. We isolate loops at the manifold, we find which loop loses pressure, and we use the tools we have to narrow the spot. A staple-up leak is often at a fitting that was buried without a reminder of where it sat. Manifolds that were labeled in pencil in 2004 are a gift. We label them in a way that survives if we are the ones who touch them.

Mixing valves and floors that are too hot

A slab does not want boiler water at 180 degrees. The mixing valve exists so the floor stays in a range that does not crack finish or cook a wood floor. A failed mixer is why the floor is either cold or too hot to stand on. We test the mixer before we talk about a new boiler. Actuators on the manifold fail one loop at a time. That looks like “the radiant died” in one room. It is an actuator.

Boiler side versus floor side

The radiant page is the floor loops. The boiler page is the machine that heats the water. A lot of “no heat” calls are a boiler that is locked out, and the floor is innocent. We check the boiler pressure and the flame, then we check whether hot water is crossing the mixer. Air in a new loop or a loop that was drained for a remodel will keep a room cold until it is purged. Purging is ordinary. It is not a new system.

Vacant houses and frozen tubing

Tubing in an exterior wall or a slab that is left unheated can freeze and split. The split shows up as a pressure loss when you fill it in the spring. Glycol and a maintained boiler are the prevention. We do not promise a slab repair will be invisible. We do promise we will not open more floor than the isolated loop requires. If the finish is tile, you should hear that tile may have to come up in that bay.

What we need from you

Manifold location, whether the system has glycol, and whether one room or the whole house is cold. Photos of the manifold save a trip. If you have the original loop drawing, leave it on the manifold. We rarely get one. License 384927. Phone 505-316-4231.

At the manifold

Loops are labeled or they get labeled. We see which actuators are open, which are dead, and whether the supply from the boiler is actually hot at the mixer. A cold manifold with a firing boiler is a pump, a mixer, or a valve, not a slab leak. A single cold loop with a dead actuator is that actuator. We replace it and we confirm the loop warms. Pressure on a glycol system is checked against the temperature, because glycol pressure moves and people drain and fill with straight water and then wonder why it froze. If you do not know whether you have glycol, we can test. Do not let anyone refill with plain water if the system was designed to sit cold.

Finding a leak without destroying the floor

Isolate, pressure test, narrow the loop. Thermal imaging helps when the floor finish allows a temperature difference to show. It does not work through every assembly, and we will not pretend it does. If the repair means lifting tile, you hear how much tile before we start. Staple-up under a crawl can often be repaired from below, which can preserve the floor finish when access is available. We take that route when it exists. A manifold fitting that is the leak is the best outcome and we look there first.

Documenting the completed repair

Pressure written down. Glycol or water written down. Loops labeled. The boiler setting that feeds the mixer written down so the next person does not turn the boiler up to 180 to “make the floor work” and cook the tubing. If a loop is abandoned because it is leaking and you chose not to open the floor, that room will not heat, and the note says the loop is capped. Call 505-316-4231 with a photo of the manifold if you can get one. It changes what we bring.

Planning new radiant heating separately

Adding radiant to a room that never had it is a construction project with a boiler or a water heater that can feed it. We will not tap a domestic water heater that is not rated for heat and call it radiant. The page you are on is repair and service of systems that already heat a floor. New work gets a walk-through and a separate price. Mixing them is how a simple actuator call turns into a remodel on the invoice.

Radiant controls, loop tests, and floor access

The manifold is the job site until it proves otherwise. Actuators, the mixer, the supply temperature, and which loop loses pressure tell us more than a story about a cold tile. A dead actuator is a part. A mixer that has failed open is why the floor is too hot. A boiler that is locked out is not a floor leak, and we will not start there with a jackhammer. When a loop does lose pressure, we isolate it and we use the access that already exists: the crawl under staple-up, the manifold fittings, the thermal difference if the finish will show it. Tile comes up only when the leak is in the slab and you have approved that mess. Glycol gets tested or identified before anyone adds water. Labels get written so the next call is shorter. New radiant in a room that has never had it is not this repair. It requires a suitable heat source, a site assessment, and a separate installation quote. If you have the original drawing, put it on the manifold before we arrive. If you do not, a phone photo of the manifold still helps. 505-316-4231. Tell us one room or the whole house, and whether the boiler is firing.

What to tell us about your radiant system

Open the cabinet, photograph the whole manifold, and photograph any gauge or mixer. If one actuator is a different color or hanging loose, that loop is the suspect. If every loop is cold and the boiler is dark, start with the boiler. If the floor is wet and the system loses pressure overnight, do not keep adding water for a week. You are feeding a leak and diluting glycol if it is there. Shut it down and call. We would rather find a manifold drip than open tile because the system was refilled until the stain showed up in the ceiling below. 505-316-4231. Say slab or under-floor if you know, and say whether the house is lived in or sitting empty.

What we actually get called for

Common problems we diagnose and repair in Santa Fe homes.

01

A cold area of floor

We check zone controls and loop flow, and investigate a leak if the evidence points to one.

02

Frequent boiler cycling

The cause may involve controls, flow, or system design. We check how the boiler and floor circuits work together.

03

Noisy manifolds

Air or circulation problems can cause noise. We check the pump and loop conditions.

04

One part of the house stays cold

A zone valve, actuator, or loop fault may be responsible. We isolate the affected area before discussing floor access.

How a job runs

01

Check the manifold and controls

We identify the affected zone and check the heat supply.

02

Test the loop

Pressure tests and thermal imaging are used where appropriate to investigate circulation or leaks.

03

Complete the repair

We explain work on pumps, valves, controls, or tubing, including any required floor access.

Questions people ask before they call

Q01

Can a radiant leak be fixed without opening the whole floor?

Sometimes. A leak at a manifold fitting or accessible tubing may be repaired without opening the floor. A leak within a slab may need localized access. We test and explain the likely access before starting.

Q02

Electric mats versus hydronic?

Electric mats heat the floor directly and are often used in individual rooms. Hydronic systems circulate warm water through tubing and may serve the whole house. The tests and repair options differ, so tell us which system you have if you know.

Q03

Do you replace PEX in a slab?

Only when testing identifies a fault that requires it. We isolate the affected loop and assess accessible connections before discussing an opening in the slab or floor finish.